Error codes E-01 to E-10 for Chinese diesel heaters explained
Your Chinese diesel parking heater suddenly shows E-01, E-03 or E-08 on the display and switches off? Don't panic – most faults have a simple cause: too little voltage, air in the fuel line or a loose plug. Here you'll find all common error codes with their meaning and the things you can check yourself.
Important first: The meaning of the codes depends on the control panel. The table shows the assignment used by most LCD control panels. Some manufacturers – for example some Vevor models – number them differently. If in doubt, check the manual of your heater.
Error codes E-01 to E-10 at a glance
| Code | Meaning | What you can check |
|---|---|---|
| E-01 | Undervoltage | Charge the battery and measure the voltage directly at the heater. Check that the positive and negative leads and the fuse are tight. Power cables that are too thin or too long are a common cause. |
| E-02 | Overvoltage | Check the charger, solar controller or alternator. Does the heater match the on-board voltage (12 V or 24 V)? |
| E-03 | Glow plug faulty | Check the glow plug connector. Measure the glow plug for an open circuit or short circuit; clean or replace a sooted plug. |
| E-04 | Fuel pump | Check the plug and cable of the dosing pump. The pump should tick audibly during start-up. Inspect the lines for leaks. |
| E-05 | Overheating / temperature sensor | Are the air intake and warm-air outlet clear? Are the ducts kinked or too long? Check the temperature sensor connector. |
| E-06 | Fan / speed sensor | Does the fan turn freely? Check that the connector and speed sensor (Hall sensor) are seated properly. |
| E-07 | Open circuit | Check the connection to the control panel: is the plug fully latched, is the cable crushed, kinked or corroded? More on this below. |
| E-08 | Flame-out | Usually a lack of fuel or air in the line: check the tank level, prime the fuel line (pump function in the menu), check the tank vent and filter. |
| E-09 | Sensor fault | Is a sensor plug loose, a cable damaged or is there a short circuit? Disconnect, inspect and reconnect the plugs. |
| E-10 | Ignition failed | Check fuel supply and fuel quality (use winter diesel in winter!), check the glow plug and fan. |
E-07, flickering or blank display: is the cable to blame?
Many problems with the control panel have nothing to do with the heater itself, but with the connection between display and heater. Typical signs:
- Error E-07 or lost connection
- The display stays blank, flickers or keeps restarting
- The heater does not respond to button presses
- Problems only occur with vibration or moisture
In this case, check the plug connections first: disconnect them, look for corrosion or bent contacts and let them click back into place. If the cable is damaged or too short and therefore under tension, a new display extension cable helps. We can repair a damaged plug with our cable repair service.
Not sure which plug your heater has? Our Cable Finder shows you the right cable in 30 seconds. See also the guide Extending the display: which plug fits?
General tips for faults
- Wait for the run-down: After a fault, switch the heater off normally and let the fan run on. Never disconnect the power while the heater is still cooling down.
- After refuelling or with an empty tank: Prime the fuel line before you try a restart.
- Avoid several start attempts in a row: Otherwise unburned fuel collects in the combustion chamber.
- White smoke on start-up: often indicates a sooted glow plug or too much fuel.
Safety first
Only work on the combustion chamber, exhaust system or fuel system if you are confident – if in doubt, ask a specialist workshop. We also recommend a CO detector inside if you use the parking heater in a motorhome, camper or workshop.
All information without guarantee. The manual of your parking heater is authoritative.